Have a Question? Contact Us

888-462-7828 Live Chat

Clear-Com HLI-2W2 2 Wire Module for HelixNet Partyline Systems

  • Dale #:

    CLEA-HLI2W2
  • Availability:

    Not in Stock - Reserve Yours
  • This item is not in stock, but we can usually ship it within 10-20 days after your order is placed. Your payment will be charged after completing checkout.

Description

HelixNet Main Stations accept both two-wire and four-wire optional interface modules, offering seamless connectivity to virtually all common two-wire and four-wire audio systems. Designing a seamless interface between analog two-wire and digital systems is no simple feat, yet Clear-Com has done j... Read More

Free Shipping (Continental US)

Have a Question?

Call Toll Free: 888-462-7828 Live Chat Email Us

Suggested Accessories

Description

HelixNet Main Stations accept both two-wire and four-wire optional interface modules, offering seamless connectivity to virtually all common two-wire and four-wire audio systems. Designing a seamless interface between analog two-wire and digital systems is no simple feat, yet Clear-Com has done just that. The HLI-2W2 Interface Module enables two-channels of Clear-Com or RTS intercom to transparently interface with digital HelixNet intercom channels. This two-wire module preserves the wideband two-wire frequency response, is conveniently packaged in a rugged, pluggable module, and is easily assignable to any of the HelixNet Main Station intercom channels.

More +

Product Specs

Dimensions7.36" x 2.24" x 1.54" (187mm x 57mm x 39mm)
Weight16oz (.454kg)
Connectors
Intercom Line(2) 3-pin XLR–F
Partyline
Maximum Level Before Clipping6dBu
Nominal Input Level-18dBu (C-C), -12dBu (RTS)
Input Impedance>= 10KO bridging
The following specified for a route to four-wire input at 0dBu in
Frequency Response100 Hz - 10 kHz ±3dB
Distortion<0.2% THD @ 1kHz
Noise<-55dBu
The following specified for a route from a four-wire output at 0dBu out
Frequency Response40 Hz - 10 kHz ±3dB
Distortion<0.2% THD @ 1 kHz
Noise<-75dBu
Auto-nulling and Echo Cancellation
RTS/Clear-Com Selectable
TerminationExternal
Power30V max external
Power Requirements0.025mA/channel
DC Voltage Range20-30 volts

More +