Have a Question? Contact Us

888-462-7828 Live Chat

Tripplite SMART2600RM2U 2U Rack 2600VA UPS System with 120V Frequency Maintenance

 
  • Dale #:

    TRIP-SMART2600RM2U
  • Availability:

    Usually ships in 10 - 20 Days
  • This item usually ships within 10-20 days after your order is placed. Your payment will be charged after completing checkout.

Description

2600VA line-interactive UPS for server, network and telecommunications equipment. 2U rackmount form factor. Corrects brownouts and overvoltages from 79V to 147V. Sine wave output. Maintains battery-derived AC output during blackouts and severe voltage fluctuations. Expandable runtime with optiona... Read More

Shipping Charges Apply

Have a Question?

Call Toll Free: 888-462-7828 Live Chat Email Us

Suggested Accessories

Description

2600VA line-interactive UPS for server, network and telecommunications equipment. 2U rackmount form factor. Corrects brownouts and overvoltages from 79V to 147V. Sine wave output. Maintains battery-derived AC output during blackouts and severe voltage fluctuations. Expandable runtime with optional external battery packs. 9 output receptacles. NEMA 5-20P input plug; NEMA L5-30P replacement plug included. Network-grade AC surge and noise suppression.

Network management interfaces include 2 USB ports, 2 DB9 serial ports and SNMPWEBCARD slot. Supports simultaneous detailed monitoring of equipment load levels, self-test data and utility power conditions via all 5 network interfaces. Includes PowerAlert monitoring software and complete cabling. Emergency Power Off (EPO) interface. Integrated 3-bank switched PDU. 3-stage metered current monitoring and battery charge LEDs. Utility power and voltage regulation LEDs. Audible alarm. Self-test. 4-post rack mounting accessories included; 2-9USTAND and 2POSTRMKITWM accessories available. Field-replaceable, hot-swappable internal batteries and battery packs. Attractive all-black color scheme.

Features

  • 2600VA / 2100 watt output power capacity compatible with North American 120V / 60Hz power
  • 2U rack/tower UPS installs in standard 19 inch rack enclosures with an installed depth of only 19 inches
  • Protects sensitive networking equipment from blackouts, voltage fluctuations and transient surges
  • Line interactive Automatic Voltage Regulation (AVR) corrects inputs from 79-147VAC back to usable 120V levels without consuming battery power
  • Dual boost AVR circuits boost undervoltages by 14% or 24% depending on the severity and reduces overvoltages by 12%
  • Network interfaces support simultaneous communications via 2 USB, 2 DB9 serial and SNMPWEBCARD slot
  • Included PowerAlert UPS monitoring software supports safe unattended shutdown, monitoring and control via local connected servers, plus any number of additional servers over IP
  • Communications ports support on-battery, low-battery, power-restored, AC-voltage, DC-voltage, output current monitoring, battery charge current, battery capacity, internal UPS temperature, AC line frequency, timed inverter shutoff, activate self-test and load bank output power control
  • Built in Emergency Power Off (EPO) interface with cable
  • Sine wave output in AC and battery modes
  • Expandable runtime with optional battery packs "– BP48V24-2U (limit 1) and BP48V60RT-3U (multi-pack compatible)
  • Half load runtime of 18 minutes with internal batteries, Add 1 BP48V24-2U for 49 minutes or 1 BP48V60RT-3U for 107 minutes (1300VA / 1050 watts)
  • Full load runtime of 6 minutes with standard internal batteries
  • Includes 9 output receptacles (4 NEMA 5-15R / 4 NEMA 5-15/20R / 1 NEMA L5-20R)
  • Ships with NEMA 5-20P input plug, user installable NEMA L5-30P replacement plug included
  • Integrated 3 bank switched PDU enables remote outlet management for load shedding or remote reboot of individual devices
  • 3 stage metered LEDs offer current monitoring and battery charge level
  • Line power and voltage regulation LEDs offer at-a-glance power status information
  • Front panel switches support self-test and alarm cancel functions
  • Included UPSRMRII adjustable mounting rails support installation in 19 inch racks with a front-to-rear depth of 23.5 and 36.5 inches (add a 2nd UPSRMRII accessory to extend the reach to 35.25 to 49.5 inches)
  • UPS ships fully assembled in full compliance with DOT regulations, no time consuming connection of internal batteries by user required
  • Supports upright tower placement with optional 2-9USTAND accessory
  • UL (USA), cUL (Canada), NOM (Mexico), FCC Class A (Emissions) listed

More +

Product Specs

Plug/Connector TypeNEMA 5-20P
Receptacles4 x NEMA 5-15R;4 x NEMA 5-20R;1 x NEMA L5-20R
Switching Time4 ms
Power Description
Load Capacity2600VA/2100W
Input Voltage110V AC
Input Voltage Range120V AC Single-phase
Output Voltage120V AC Single-phase
Frequency60Hz
Waveform TypeSine Wave
FilteringEMI / RFI
Management
Network ManageabilitySNMP Manageable Optional
Overload ProtectionResettable circuit breaker
Audible AlarmsOn Battery;Overload;Low Battery
Emergency Power OFFYes
Controls/Indicators
Status Indicators5 front panel LEDs - Green POWER LED, Green VOLTAGE CORRECTION LED, 3 color BATTERY CHARGE LED, 3 color OUTPUT LOAD LED, red BATTERY WARNING LED
Interfaces/Ports
Interfaces/Ports2 x DB-9;2 x USB
Modular Slots1 x Communications Slot
Battery Information
BatteriesSealed Lead-acid User-replaceable Hot-swappable
Backup/Run Time6 Minute(s) 2600VA Full-load;18 Minute(s) 1300VA Half-load
Battery Life3 Year(s) to 6 Year(s)
Battery Recharge Time4 Hour(s)
Environmental Conditions
Temperature32 °F (0 °C) to 104 °F (40 °C) Operating
Humidity0 to 95% Non-condensing Relative Humidity
Physical Characteristics
Form Factor2U Rack-mountable
Power Cord/Cable10 ft
Shipping Dimensions9 Height x 23.5 Width x 20 Depth
Shipping Weight72 lb

More +

Shipping Rate Calculator

 

Also Popular