Have a Question? Contact Us

888-462-7828 Live Chat

Williams Sound DL107 NET D Induction Loop Amplifier w/ Network Control And Dante Digital Inputs

 
  • Dale #:

    WISO-DL107NETD
  • Availability:

    Not in Stock - Reserve Yours
  • This item is not in stock, but we can usually ship it within 10-20 days after your order is placed. Your payment will be charged after completing checkout.

Description

Digi-Loop is definitely state-of-the-art - the first of its kind to maximize modern amplifier technology. Its network-control capability provides seamless, remote system set-up, operation and monitoring via laptop or tablet. DSP audio processing offers flexible, powerful software control of mixin... Read More

Free Shipping (Continental US)

Have a Question?

Call Toll Free: 888-462-7828 Live Chat Email Us

Suggested Accessories

Description

Digi-Loop is definitely state-of-the-art - the first of its kind to maximize modern amplifier technology. Its network-control capability provides seamless, remote system set-up, operation and monitoring via laptop or tablet. DSP audio processing offers flexible, powerful software control of mixing, equalization, compression and more. Powerful Class D, pulse-width amplifiers maximize efficiency.
The Digi-Loop’s amplifier design offers either single or dual 9.5 A rms loop outputs for perimeter loop(s), single array(s), dual loop, or phased-array configuration. A 70-100 V input provides connection to a distributed speaker/paging system, ensuring announcements are heard by loop users.

System Includes:

  • (1) PLA DL107 NET Loop Amplifier
  • (1) WLC 004 Line Cord (US)
  • (1) IDP 009 ADA Wall Plaque (T-Coil)

Features:

  • Network control - allows control and calibration of unit remotely with application software
  • High continuous current 9.5 Arms (13.4 Apk) per output continuous
  • LCD Screen with VU metering, easy one-button menu control
  • DSP Audio Processing
  • Dante™ Input ("D" models)
  • USB for firmware updates
  • Input mixing, parametric equalization, compression, metal compensation, high and low-pass filters, AGC and audio delay
  • Power-save mode
  • Adjustable output delay for multiple amps in large venues
  • Fault warning and active protection against shorted or open circuits and overheating
  • Loop fault relay output
  • XLR and 3-position terminal block input configurable as microphone input or line-input, balanced or unbalanced
  • Standard 1 RU, 19" rackmount
  • Magnetic signal couples directly to devices equipped with telecoils (T-coils) such as hearing aids, cochlear implants, or optional loop receivers
  • DL207 suitable for phased-array or dual-loop systems; DL107 suitable for perimeter loop or single array
  • Phased-array mode automatically produces 90° phase shift in slave loop output
  • Meets IEC 60118-4 system performance requirements when integrated into a correctly designed and installed system
  • Meets IEC Specification 60118-4 (when designed and commissioned properly)
  • Tested to IEC Specifications 62489-1 Benchmark Standards

More +

Product Specs

N/A
DL 107 NET
GENERAL
Dimensions1 RU Rackmount, 19" W x 1.75" H x 10" D. Chassis is 17" W.
WeightDL107: 9.2 lbs (4.2 kg)
DL207: 9.2 lbs (4.2 kg)
ColorCase: Black, white and blue legends on front, white legends on back. LCD: Backlit Blue
Fan coolingVariable Speed, Temperature Controlled
Power SupplyInternal, Universal 100-240 VAC, 50/60 Hz, 200 Watt. Fuse: 5 x 20 mm, 5 A, 250 V. AC power plug is IEC 320-C14
Heat output @ 120 VACDL107 : Sleep State: 63 BTU/hr; Idle State: 71 BTU/hr; Driving one loop @ 9.5 A: 339 BTU/hr
DL207: Sleep State: 63 BTU/hr; Idle State: 84 BTU/hr; Driving two loops @ 9.5 A each: 638 BTU/hr
Ethernet(1x) RJ-45; 10-100 MBps
USB(1x) standard-B. USB 1.1, 2.0 or 3.0 supported
Environment0-35° C ( 32-95° F), 0-90% relative humidity
Coverage AreaDL207 (dual output amplifier):
30,000 sq. ft. (2,786 sq. m.) (Perimeter Loops, 3:1 aspect ratio, both outputs driven)
18,000 sq. ft. (1,672 sq. m.) (Perimeter Loops, 1:1 aspect ratio, both outputs driven)
DL107 (single output amplifier):
15,000 sq. ft. (1,393 sq. m.) (Perimeter Loop, 3:1 aspect ratio)
9,000sq. ft. (836 sq. m.) (Perimeter Loop, 1:1 aspect ratio)
INPUTS
Dante inputOn "D" models only. (1x) RJ-45;100 Mbps. Minimum latency: 2 ms. Audio sample rates supported: 44.1, 48 kHz. Resolution: 24 bits
Line inputs(1x) 3-position terminal block, 10 k? input impedance. Configurable/accepts -10 dBV, -4 dBu, +4 dBu, +8 dBu, balanced or unbalanced. Level adjustable 0 to -96 dB
Mic/Line inputs(1x) XLR 3-pin jack. Input impedance: 1.5 k? Mic, 10 k? Line. Configurable/Accepts: Mic, Line -10 dBV, Line +4 dBu, or Line +8 dBu, balanced or unbalanced. Phantom supply (24V)
70-100 V input(1x) 2-position terminal block; high/speaker-level input (accepts 25 V, 70 V or 100 V) from distributed audio/paging systems
OUTPUTS
Line outputs(1x) 3-position terminal block; loop-through of Mic/Line Input 1 and Line Input 2, +4 dBu, Balanced or Unbalanced. The line outputs mirror the audio of the loop output
Loop output(s)(1x) 2-position terminal block per output
Audio output delayAdjustable from 0 to 165 msec
Headphone output(1x) 1/4" stereo headphone jack, on front of unit. Monitored input or output selectable in menu
Loop fault relay(1x) 3-position terminal block providing NC, NO and Common. Contact rating: 2.0 A @ 30 VDC
Loop output drive voltage16.1 Vrms (22.8 Vpk) continuous
Rated loop output current9.5 Arms (13.4 Apk) per output
Loop resistance range0.5 ? to 3.0 ? (DC)
AUDIO
Rated load0.5 ? DC with 135 µH inductance
Frequency response45 Hz to 9.0 kHz ± 2 dB (1 kHz ref.)
Rated loop THD<1 % at rated output current (1 kHz sine wave)
OTHER
Front controlsFront LCD display menu access/adjustment via control button/dial
Adjustable settingsInput mixing, parametric equalization, compression, metal loss compensation, high and low-pass filters, AGC and audio delay, output levels. See User Manual for adjustment range(s)
Internal calibration toolsTest tone generator with pink noise, loop current adjustment/matching. See User Manual for details
Other featuresSave/load configuration, loop test, priority input selection with adjustable threshold, loop fault relay, open/short and thermal protection. See User Manual for details
Network control and firmwareFunction control and calibration by DigiLoop PC App via ethernet (RJ-45). PC App requires Windows 7 or higher. Firmware updates through USB only
Warranty5 years
ApprovalsCE, UL, ULC, FCC, Industry Canada, RoHS, WEEE, CB scheme, RCM
Standards complianceThis product is designed to meet the IEC-60118-4 standard when correctly designed, installed and commissioned. Test Specifications provided to the IEC 62489-1 standard

NOTE: SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE.