Contact Our Expert Sales Team:

888-462-7828

RDL FP-BUC2 2-Channel Balanced to Unbalanced Audio Converter

  • Dale #:

    RDL-FPBUC2
  • Availability:

    Not in Stock - Reserve Yours
  • This item is not in stock and needs to be ordered from the manufacturer. Your payment will be charged after completing checkout. We will strive to ship as soon as possible, pending availability.

Please Note: requires PS-24AS Power Supply (sold separately)

Description

The FP-BUC2 is the ideal choice for connectorized conversion from balanced to unbalanced audio. This module features two identical active (transformerless) channels. Gold contact XLR jacks are utilized for the balanced input channels. Each output is unbalanced, connected through a gold-plated pho... Read More

Free Shipping (Continental US)

Have a Question?

Call Toll Free: 888-462-7828 Live Chat Email Us

Suggested Accessories

Description

The FP-BUC2 is the ideal choice for connectorized conversion from balanced to unbalanced audio. This module features two identical active (transformerless) channels. Gold contact XLR jacks are utilized for the balanced input channels. Each output is unbalanced, connected through a gold-plated phono jack. A level trim potentiometer is provided for each channel.

The FP-BUC2 circuitry features low-noise, low-distortion and excellent headroom and crosstalk performance and the superior audio clarity for which RDL products are known. The FP-BUC2™s low profile and compact size permit mounting in confined spaces and in various locations in equipment racks.
    Features:
  • Stereo Balanced to Unbalanced Audio Conversion
  • Connectorized Audio Converter
  • Output Level Trim
  • Low-Noise and Low-Distortion Conversion
  • Cabinet, Shelf or Rack Mounting
  • Convenience of RDL FLAT-PAKs&trade

The normal gain setting is indicated for the trimming potentiometer. This setting produces a +4 dBu balanced output for a –10 dBV unbalanced input. The gain is adjustable –5 dB to +10 dB from the normal gain. Therefore, a +4 dBu output signal is possible from input signals ranging from –20 dBV to –5 dBV.

More +

Product Specs

Amps per FP-BUC2: 2 identical circuits (stereo or dual mono operation)
Gain: +/- 6 dB (adjustable relative to “10 dBV output for +4 dBu input) (separate controls for each channel)
Input Level: “2 dBu to +10 dBu (for -10 dBV output)
Input Impedance: 20 k
Input Configuration: Balanced bridging
Output Level: -10 dBV
Output Impedance: 75 (drives 600 or 10 k unbalanced lines)
Output Configuration: Unbalanced
Frequency Response: 10 Hz to 40 kHz (+/- 0.1 dB)
THD+N: < 0.005% (10 Hz to 40 kHz)
IMD: < 0.005%
Headroom: > 18 dB (at rated output level of -10 dBV)
Noise: < -90 dB (referred to -10 dBV, 20 Hz to 20 kHz)
Typ. “95 dB (rel. “10 dBV, A-Weighted)
CMRR: > 50 dB (20 Hz to 5 kHz)
Crosstalk: Better than -90 dB (20 Hz to 20 kHz)
Power Requirement: GROUND-REFERENCED, 24 Vdc @ 50 mA
Dimensions:
Height: 1.29 in.   3.28 cm
Width: 3.25 in.   8.26 cm
Length: 4.07 in.   10.34 cm
Ambient Operating Environment:0 degrees C to 55 degrees C

More +