Description
Bogen's Power Vector modular amplifiers offer a wide range of power levels from which to choose, with five models from 35W to 250W. The amplifiers are designed to work with both high- (70/25V) and low- (4/8-ohm) impedance speaker systems. Each model includes eight module bays for plug-in input modules and allows up to four levels of priority between modules. Two module bays are capable of accepting plug-in signal-processing output modules. Each module is controlled by an independent volume control with an associated signal/clip LED for signal status. An 11-segment LED?output meter monitors output signal level. Each model includes a motorized master volume control that can be controlled using a remote volume control panel (RVCP, sold separately).
Features:
- 5 models ranging from 35W to 250W each; a mixer-only version (VMIX) is also available
- Capable of handling 70V, 25V, 8-ohm, and 4-ohm speaker loads
- 8 module bays
- Wide selection of advanced plug-in modules (modules sold separately)
- 4 levels of priority between modules
- 2 module bays capable of handling plug-in signalprocessing output modules
- 11-segment LED?output level meter monitors the output level of the power amplifier with Avg./Peak meter switch
- Motorized master volume control can be remotely operated
- Lockable switch permits user to select either transformer-coupled outputs or a direct lowimpedance output
- 5-position barrier strip, with clamping washers, provides connections for speaker loads
- Bridging In/Out connector
- External access to priority mute buses
- Bridging jack and Mute terminals join multiple Power Vector amps and mixers together
- Independent volume control for each of the eight module bays
- Two-color LED for each channel indicates input signal or clipping
- Bass and treble control with bypass switch (located in module bay 6)
- 125 Hz Low Cut switch (located in module bay 6)
- Signal-processing insert jacks allow external equipment to be inserted between the pre-amp output and the power amp input
- Pre-EQ, unbalanced, buffered output signal ("post" all unit controls, but "pre" any external "Insert" equipment connected)
- Grounded, unswitched AC convenience receptacle with a 500W maximum capacity provided for external equipment
- 8 module security cover/filler plates included with amplifier (PVMC)
- Push-button remote volume control panel (Model RVCP, sold separately)
- Security cover to selectively protect volume, bass, and treble controls (Model PVSC, sold separately)
- Rack mountable (with rack mounting kit RPK87, sold separately)
- 2 rack spaces high (3-1/2")
- Listed to UL Standard 60065 for U.S. and Canada
Power Output (RMS) | Rated: 60W Typical @ 1KHz: 85W |
Frequency Response | Transformer: 45 Hz to 20 kHz; +0/-2 dB Direct: 20 Hz to 20 kHz; +0/-1 dB |
Distortion | Transformer: < 0.5% Direct: < 0.1% (.05 typical @ 1 kHz) |
Signal-to-Noise | Fundamental: -94 dB With SAX1R Module: -70 dB With MIC1S Module: -60 dB With TEL1S Module: -70 dB |
Tone Controls | Bass Frequency: @100 Hz (+/- 10 dB minimum) Treble Frequency: @10 kHz (+/- 10 dB minimum) Low Cut Frequency: @125 Hz (-6 dB/octave) |
Sensitivity | 0.4V (at backplane connector) |
Output Regulation | 2 dB or better, no load to full load |
Output Impedance | Transformer-Coupled: 70V, 25V, 8 ohms (bal or unbal) Direct Coupled: 4 ohms (minimum) |
Thermal Emissions (BTU/hr.) | 204.9 |
Inserts | Insert "OUT" Level: 1VRMS (@FRP) Insert "OUT" Impedance: 50 ohms maximum Insert "IN" Sensitivity: 1VRMS Insert "IN" Impedance: 10k ohms minimum |
Bridging In/Out | Bus Level: 250 mVRMS (@FRP) Bus Impedance: 10k ohms maximum |
Pre-EQ Output | Output Level: 4VRMS (@FRP) Output Impedance: 50 ohms maximum |
AC_Power Receptacle | 500 watts maximum power, unswitched |
AC Voltage | 120V AC, 60 Hz |
AC Current | 1.3A |
Product Weight (lb.) | 26 |
Dimensions | 17-1/4" W x 3-7/8" H x 14-3/4" D |
Bogen's Power Vector modular amplifiers offer a wide range of power levels from which to choose, with five models from 35W to 250W. The amplifiers are designed to work with both high- (70/25V) and low- (4/8-ohm) impedance speaker systems. Each model includes eight module bays for plug-in input modules and allows up to four levels of priority between modules. Two module bays are capable of accepting plug-in signal-processing output modules. Each module is controlled by an independent volume control with an associated signal/clip LED for signal status. An 11-segment LED?output meter monitors output signal level. Each model includes a motorized master volume control that can be controlled using a remote volume control panel (RVCP, sold separately).
Features:
- 5 models ranging from 35W to 250W each; a mixer-only version (VMIX) is also available
- Capable of handling 70V, 25V, 8-ohm, and 4-ohm speaker loads
- 8 module bays
- Wide selection of advanced plug-in modules (modules sold separately)
- 4 levels of priority between modules
- 2 module bays capable of handling plug-in signalprocessing output modules
- 11-segment LED?output level meter monitors the output level of the power amplifier with Avg./Peak meter switch
- Motorized master volume control can be remotely operated
- Lockable switch permits user to select either transformer-coupled outputs or a direct lowimpedance output
- 5-position barrier strip, with clamping washers, provides connections for speaker loads
- Bridging In/Out connector
- External access to priority mute buses
- Bridging jack and Mute terminals join multiple Power Vector amps and mixers together
- Independent volume control for each of the eight module bays
- Two-color LED for each channel indicates input signal or clipping
- Bass and treble control with bypass switch (located in module bay 6)
- 125 Hz Low Cut switch (located in module bay 6)
- Signal-processing insert jacks allow external equipment to be inserted between the pre-amp output and the power amp input
- Pre-EQ, unbalanced, buffered output signal ("post" all unit controls, but "pre" any external "Insert" equipment connected)
- Grounded, unswitched AC convenience receptacle with a 500W maximum capacity provided for external equipment
- 8 module security cover/filler plates included with amplifier (PVMC)
- Push-button remote volume control panel (Model RVCP, sold separately)
- Security cover to selectively protect volume, bass, and treble controls (Model PVSC, sold separately)
- Rack mountable (with rack mounting kit RPK87, sold separately)
- 2 rack spaces high (3-1/2")
- Listed to UL Standard 60065 for U.S. and Canada
Power Output (RMS) | Rated: 60W Typical @ 1KHz: 85W |
Frequency Response | Transformer: 45 Hz to 20 kHz; +0/-2 dB Direct: 20 Hz to 20 kHz; +0/-1 dB |
Distortion | Transformer: < 0.5% Direct: < 0.1% (.05 typical @ 1 kHz) |
Signal-to-Noise | Fundamental: -94 dB With SAX1R Module: -70 dB With MIC1S Module: -60 dB With TEL1S Module: -70 dB |
Tone Controls | Bass Frequency: @100 Hz (+/- 10 dB minimum) Treble Frequency: @10 kHz (+/- 10 dB minimum) Low Cut Frequency: @125 Hz (-6 dB/octave) |
Sensitivity | 0.4V (at backplane connector) |
Output Regulation | 2 dB or better, no load to full load |
Output Impedance | Transformer-Coupled: 70V, 25V, 8 ohms (bal or unbal) Direct Coupled: 4 ohms (minimum) |
Thermal Emissions (BTU/hr.) | 204.9 |
Inserts | Insert "OUT" Level: 1VRMS (@FRP) Insert "OUT" Impedance: 50 ohms maximum Insert "IN" Sensitivity: 1VRMS Insert "IN" Impedance: 10k ohms minimum |
Bridging In/Out | Bus Level: 250 mVRMS (@FRP) Bus Impedance: 10k ohms maximum |
Pre-EQ Output | Output Level: 4VRMS (@FRP) Output Impedance: 50 ohms maximum |
AC_Power Receptacle | 500 watts maximum power, unswitched |
AC Voltage | 120V AC, 60 Hz |
AC Current | 1.3A |
Product Weight (lb.) | 26 |
Dimensions | 17-1/4" W x 3-7/8" H x 14-3/4" D |
We are your source for all your pro audio needs, delivered by experts. Call us today.