DALE SKU # DPA-ST4011A

DPA Microphones ST4011A - Stereo Pair of 4011A Microphones with Accessories and Case

Sale price$4,730.00
  • Availability:

    Special Order Item
  • This item is not stocked and needs to be ordered from the manufacturer. Please contact our sales team for more information.


  • LET OUR TEAM OF EXPERTS ASSIST YOU

    Description

    This condenser microphone is renowned in recording studios and live applications around the world as an exceptional mic. State-of-the-art components have been carefully selected to provide optimal neutrality, accuracy and extremely low distortion.

    Even though the standard tolerances on our recording microphones are extremely low, a stereo match is even closer. These specially selected 4011A Cardioid Microphones are matched within ±1 dB on both frequency response and sensitivity. The pair comes in a heavy-duty Peli™ Case for safe transportation and easy access to the microphones and accessories.

    Features:

    • Modularity – interchangable capsules and preamplifiers
    • Up to 120 dB dynamic range
    • RF rejection between 60 and 40 dB
    • Linear frequency response
    • High SPL
    • Superior gain before feedback


    The 4011 Cardioid Microphone
    The principal appeal of the 4011 Cardioid Microphone is its directional quality and attention to detail. This mic makes everything sounds like the original. The first-order cardioid pickup pattern provides superb separation between sound sources.

    It is equally suitable for close-up work on acoustic guitar, grand piano, overheads, percussion, wind instruments and vocals as it is for spot-miking symphonies. It can handle incredibly high sound levels and even includes a 20 dB pad switch in the center of the XLR connector to attenuate the output of the microphone.

    A flat on-axis frequency response and excellent phase response deliver a totally faithful reproduction of the original sound. The off-axis response is similarly smooth so that any leakage is an accurate reflection of the original, though attenuated according to the true first-order cardioid pickup pattern.

    Directional pattern Cardioid
    Principle of operation Pressure gradient
    Cartridge type Pre-polarized condenser
    Frequency response 20 Hz - 20 kHz
    Effective frequency range, ±2 dB, at 30 cm (11.8 in) 40 Hz - 20 kHz
    Sensitivity, nominal, ±2 dB at 1 kHz 10 mV/Pa; -40 dB re. 1 V/Pa
    Equivalent noise level, A-weighted Typ. 18 dB(A) re. 20 µPa (max. 20 dB(A))
    Equivalent noise level, ITU-R BS.468-4 Typ. 25 dB (max. 27 dB)
    Distortion, THD < 1% 136 dB SPL RMS, 139 dB SPL peak
    Dynamic range Typ. 121 dB
    Max. SPL, THD 10% 159 dB SPL peak
    Switchable attenuator, filters etc. 0 dB / -20 dB
    Rated output impedance 200 ?
    Minimum load impedance 2 k?
    Cable drive capability 100 m (328 ft)
    Output balance principle Impedance balancing with Active Drive
    Common mode rejection ratio (CMRR) > 60 dB
    Power supply (for full performance) P48 (Phantom Power)
    Current consumption 2.8 mA
    Connector XLR-3M. Pin 1: shield, Pin 2: signal + phase, Pin 3: - phase
    Color Matte black
    Weight 158 g (5.6 oz)
    Microphone diameter 19 mm (0.75 in)
    Capsule diameter 19 mm (0.75 in)
    Microphone length 170 mm (6.7 in)
    Maximum output voltage, RMS 8 V
    Polarity +V at pin 2 for positive sound pressure
    Temperature range -40¡C to 45¡C (-40¡F to 113¡F)
    Relative humidity (RH) Up to 90%
    Matching tolerance (frequency response and sensitivity) ±1 dB
    Phase deviation for kit < 10¡

    This condenser microphone is renowned in recording studios and live applications around the world as an exceptional mic. State-of-the-art components have been carefully selected to provide optimal neutrality, accuracy and extremely low distortion.

    Even though the standard tolerances on our recording microphones are extremely low, a stereo match is even closer. These specially selected 4011A Cardioid Microphones are matched within ±1 dB on both frequency response and sensitivity. The pair comes in a heavy-duty Peli™ Case for safe transportation and easy access to the microphones and accessories.

    Features:

    • Modularity – interchangable capsules and preamplifiers
    • Up to 120 dB dynamic range
    • RF rejection between 60 and 40 dB
    • Linear frequency response
    • High SPL
    • Superior gain before feedback


    The 4011 Cardioid Microphone
    The principal appeal of the 4011 Cardioid Microphone is its directional quality and attention to detail. This mic makes everything sounds like the original. The first-order cardioid pickup pattern provides superb separation between sound sources.

    It is equally suitable for close-up work on acoustic guitar, grand piano, overheads, percussion, wind instruments and vocals as it is for spot-miking symphonies. It can handle incredibly high sound levels and even includes a 20 dB pad switch in the center of the XLR connector to attenuate the output of the microphone.

    A flat on-axis frequency response and excellent phase response deliver a totally faithful reproduction of the original sound. The off-axis response is similarly smooth so that any leakage is an accurate reflection of the original, though attenuated according to the true first-order cardioid pickup pattern.

    Directional pattern Cardioid
    Principle of operation Pressure gradient
    Cartridge type Pre-polarized condenser
    Frequency response 20 Hz - 20 kHz
    Effective frequency range, ±2 dB, at 30 cm (11.8 in) 40 Hz - 20 kHz
    Sensitivity, nominal, ±2 dB at 1 kHz 10 mV/Pa; -40 dB re. 1 V/Pa
    Equivalent noise level, A-weighted Typ. 18 dB(A) re. 20 µPa (max. 20 dB(A))
    Equivalent noise level, ITU-R BS.468-4 Typ. 25 dB (max. 27 dB)
    Distortion, THD < 1% 136 dB SPL RMS, 139 dB SPL peak
    Dynamic range Typ. 121 dB
    Max. SPL, THD 10% 159 dB SPL peak
    Switchable attenuator, filters etc. 0 dB / -20 dB
    Rated output impedance 200 ?
    Minimum load impedance 2 k?
    Cable drive capability 100 m (328 ft)
    Output balance principle Impedance balancing with Active Drive
    Common mode rejection ratio (CMRR) > 60 dB
    Power supply (for full performance) P48 (Phantom Power)
    Current consumption 2.8 mA
    Connector XLR-3M. Pin 1: shield, Pin 2: signal + phase, Pin 3: - phase
    Color Matte black
    Weight 158 g (5.6 oz)
    Microphone diameter 19 mm (0.75 in)
    Capsule diameter 19 mm (0.75 in)
    Microphone length 170 mm (6.7 in)
    Maximum output voltage, RMS 8 V
    Polarity +V at pin 2 for positive sound pressure
    Temperature range -40¡C to 45¡C (-40¡F to 113¡F)
    Relative humidity (RH) Up to 90%
    Matching tolerance (frequency response and sensitivity) ±1 dB
    Phase deviation for kit < 10¡

    Your home for all things pro audio—backed by expertise and experience. Connect with us today.

    Your home for all things pro audio—backed by expertise and experience. Connect with us today.