DALE SKU # NEUM-TLM102BKSTUDIOSET

Neumann TLM 102 BK STUDIO SET Cardioid Condenser Microphone (Black)

Sale price$899.00 Regular price$1,049.00
Save $150.00

Please Note: Orders will not be available for shipment until on or about Wednesday August, 19.


LET OUR TEAM OF EXPERTS ASSIST YOU

Description

Packaged with the EA 4 shockmount.

The TLM 102 is impressive in terms of sound: In the interior is a newly developed large-diaphragm capsule (cardioid) with a maximum sound pressure level of 144 dB, which permits the recording of percussion, drums, amps and other very loud sound sources, for example. Instruments that are not especially loud also benefit from the very fast transient response of the TLM 102. However its most important applications are in the realm of vocals and speech; a slight boost above 6 kHz provides for excellent presence of the voice in the overall mix. Up to 6 kHz the frequency response is extremely linear, ensuring minimal coloration and a clearly defined bass range. The capsule has an elastic suspension for the suppression of structure-borne noise. A pop screen integrated into the grille serves to suppress plosives in vocal and speech recording.

Features:

  • Large-diaphragm microphone with cardioid directional characteristic (pressure gradient transducer)
  • Compact, characteristic but smaller-scale Neumann design
  • Very high maximum sound pressure level
  • Slight presence boost above 6 kHz
  • Transformerless circuitry

Due to its price and flexible field of application, the TLM 102 is ideal for the home recording and project studio sector, as well as for the broadcasting area, especially when clear lines of sight to the speakers are a priority.

The reduced overall size contributes to an exceptionally compact appearance, which unites all of the typical design components of a Neumann microphone. The harmonious proportions and gleaming grille ring ensure that even at first glance, the TLM 102* attracts attention.

Acoustical operating principlePressure gradient transducer
Directional patternCardioid
Frequency range20 Hz ... 20 kHz
Sensitivity at 1 kHz into 1 kohm11 mV/Pa
Rated impedance50 ohms
Rated load impedance1 kohms
Equivalent noise level, CCIR1)21 dB
Equivalent noise level, A-weighted1)12 dB-A
Signal-to-noise ratio, CCIR1)Ê(rel. 94 dB SPL)73 dB
Signal-to-noise ratio, A-weighted1)Ê(rel. 94 dB SPL)82 dB
Maximum SPL for THD 0.5%2)144 dB
Maximum output voltage13 dBu
Supply voltage (P48, IEC 61938)48 V ± 4 V
Current consumption (P48, IEC 61938)3.5 mA
Matching connectorXLR3F
Weightapprox. 210 g
Diameter52 mm
Length116 mm

Packaged with the EA 4 shockmount.

The TLM 102 is impressive in terms of sound: In the interior is a newly developed large-diaphragm capsule (cardioid) with a maximum sound pressure level of 144 dB, which permits the recording of percussion, drums, amps and other very loud sound sources, for example. Instruments that are not especially loud also benefit from the very fast transient response of the TLM 102. However its most important applications are in the realm of vocals and speech; a slight boost above 6 kHz provides for excellent presence of the voice in the overall mix. Up to 6 kHz the frequency response is extremely linear, ensuring minimal coloration and a clearly defined bass range. The capsule has an elastic suspension for the suppression of structure-borne noise. A pop screen integrated into the grille serves to suppress plosives in vocal and speech recording.

Features:

  • Large-diaphragm microphone with cardioid directional characteristic (pressure gradient transducer)
  • Compact, characteristic but smaller-scale Neumann design
  • Very high maximum sound pressure level
  • Slight presence boost above 6 kHz
  • Transformerless circuitry

Due to its price and flexible field of application, the TLM 102 is ideal for the home recording and project studio sector, as well as for the broadcasting area, especially when clear lines of sight to the speakers are a priority.

The reduced overall size contributes to an exceptionally compact appearance, which unites all of the typical design components of a Neumann microphone. The harmonious proportions and gleaming grille ring ensure that even at first glance, the TLM 102* attracts attention.

Acoustical operating principlePressure gradient transducer
Directional patternCardioid
Frequency range20 Hz ... 20 kHz
Sensitivity at 1 kHz into 1 kohm11 mV/Pa
Rated impedance50 ohms
Rated load impedance1 kohms
Equivalent noise level, CCIR1)21 dB
Equivalent noise level, A-weighted1)12 dB-A
Signal-to-noise ratio, CCIR1)Ê(rel. 94 dB SPL)73 dB
Signal-to-noise ratio, A-weighted1)Ê(rel. 94 dB SPL)82 dB
Maximum SPL for THD 0.5%2)144 dB
Maximum output voltage13 dBu
Supply voltage (P48, IEC 61938)48 V ± 4 V
Current consumption (P48, IEC 61938)3.5 mA
Matching connectorXLR3F
Weightapprox. 210 g
Diameter52 mm
Length116 mm

Your home for all things pro audio—backed by expertise and experience. Connect with us today.

Your home for all things pro audio—backed by expertise and experience. Connect with us today.