    STUDIO SET of the TLM 107 includes case and EA 4 shockmount.

    The freedom of sound - the tlm 107

    Multifaceted versatility, nocompromise sound and innovative operation: With five directional characteristics and a novel operating concept, this standard setting large diaphragm microphone provides sound with out any coloration. Featuring equally impressive level handling and low selfnoise, it captures everything from the softest whisper to thundering drums. For studio, broadcasting and demanding home recording applications. Classic proportions combined with attractive styling and fresh ideas - the TLM 107 perfectly embodies the Neumann philosophy: Innovation based on tradition. Far from evoking vintage or retro nostalgia, the standard setting TLM 107 represents an impressive, modern studio microphone. Its extensive performance spectrum and high precision reproduction, very close to the original, make the TLM 107 universally applicable, opening up the widest freedom in mixing and postproduction.

    Features:

    • Multipattern large diaphragm microphone with 5 polar patterns (omni, wide cardioid, cardioid, hypercardioid, figure eight)
    • Navigation switch with LED illuminated display for polar pattern, PAD and low cut
    • Sound characteristics: transparent, natural reproduction of human voice, outstanding transient response
    • Balanced sound in all 5 polar pattern settings

    Neumann Engineering

    The newly developed sound transducer, inspired by one of Neumann's top-of- the-line microphones, the D-01, is impressive with its outstanding impulse fidelity. The great consistency of the five polar patterns, omnidirectional, cardioid and figure-8, with the intermediate patterns wide-angle cardioid and hypercardioid, is also unusual for a large-diaphragm capsule. The TLM 107 provides optimal sound not only for the cardioid setting; it also ensures maximum precision over the entire frequency range for all of the other directional characteristics. The sound always remains balanced, with an almost linear reproduction up to 8 kHz, and a slight boost in the highest frequencies that lends presence and freshness to the voice. Here particular attention has been paid to the natural reproduction of speech sounds, especially the critical "s" sound. The grille is acoustically optimized for low sensitivity to pop sounds. In addition, the sound transducer is edge-terminated, with both diaphragms at ground voltage. Specifically, this ensures considerably reduced sensitivity to dust and humidity.

    No-Compromise Sound Design

    Transformerless circuitry permits a high degree of linearity and a large dynamic range. The self-noise of only 10 dB-A is practically inaudible, while at the same time, the TLM 107 features high level handling. The maximum sound pressure level of 141 dB SPL can be increased to 153 dB SPL via pre-attenuation (Pad). This enables the TLM 107 to transmit the sound of even the loudest instruments without distortion. The Low Cut settings of Linear, 40 Hz, and 100 Hz are precisely adapted to practical recording situations. Without side effects, the 40 Hz setting cuts interference noise below the range of fundamental tones (where 41 Hz is the frequency of the double bass open E string), while the 100 Hz setting is optimized for speech and vocals (where 100 Hz corresponds to the lowest notes of a baritone).

    Innovative Operating Concept

    For the first time, all of the microphone switch functions are controlled intuitively via a navigation switch. A visual highlight is the illuminated pattern display in the chrome ring, while the Pad and Low Cut status is displayed by LEDs to the left and right of the switch. In order not to distract singers, the switch and display are located on the back of the microphone. After 15 seconds, the displays are turned off automatically.

    Specifications
    Acoustical operating Pressure gradient transducer
    Directional patternOmnidirectional, wide angle cardioid, cardioid, hypercardioid, gure-8
    Frequency range20 Hz...20 kHz
    Sensitivity at 1 kHz into 1 kohm11 mV/Pa
    Rated impedance50 ohms
    Rated load impedance1 kohms
    Equivalent noise level, CCIR1)22 dB
    Equivalent noise level, A-weighted1)10 dB-A
    Signal-to-noise ratio, CCIR1) (rel. 94 dB SPL) 72 dB
    Signal-to-noise ratio, A-weighted1) (rel. 94 dB SPL)84 dB
    Maximum SPL for THD 0.5%2)141 dB
    with preattenuation -6 dB 147 dB
    with preattenuation-12 dB 153 dB
    Max. output voltage for THD>0.5%10 dBu
    Supply voltage (P48, IEC 61938)48 V ± 4 V
    Current consumption (P48, IEC 61938)3,2 mA
    Matching connectorXLR3F
    Weight approx.445 g
    Diameter 64 mm
    Length 145 mm

    STUDIO SET of the TLM 107 includes case and EA 4 shockmount.

    The freedom of sound - the tlm 107

    Multifaceted versatility, nocompromise sound and innovative operation: With five directional characteristics and a novel operating concept, this standard setting large diaphragm microphone provides sound with out any coloration. Featuring equally impressive level handling and low selfnoise, it captures everything from the softest whisper to thundering drums. For studio, broadcasting and demanding home recording applications. Classic proportions combined with attractive styling and fresh ideas - the TLM 107 perfectly embodies the Neumann philosophy: Innovation based on tradition. Far from evoking vintage or retro nostalgia, the standard setting TLM 107 represents an impressive, modern studio microphone. Its extensive performance spectrum and high precision reproduction, very close to the original, make the TLM 107 universally applicable, opening up the widest freedom in mixing and postproduction.

    Features:

    • Multipattern large diaphragm microphone with 5 polar patterns (omni, wide cardioid, cardioid, hypercardioid, figure eight)
    • Navigation switch with LED illuminated display for polar pattern, PAD and low cut
    • Sound characteristics: transparent, natural reproduction of human voice, outstanding transient response
    • Balanced sound in all 5 polar pattern settings

    Neumann Engineering

    The newly developed sound transducer, inspired by one of Neumann's top-of- the-line microphones, the D-01, is impressive with its outstanding impulse fidelity. The great consistency of the five polar patterns, omnidirectional, cardioid and figure-8, with the intermediate patterns wide-angle cardioid and hypercardioid, is also unusual for a large-diaphragm capsule. The TLM 107 provides optimal sound not only for the cardioid setting; it also ensures maximum precision over the entire frequency range for all of the other directional characteristics. The sound always remains balanced, with an almost linear reproduction up to 8 kHz, and a slight boost in the highest frequencies that lends presence and freshness to the voice. Here particular attention has been paid to the natural reproduction of speech sounds, especially the critical "s" sound. The grille is acoustically optimized for low sensitivity to pop sounds. In addition, the sound transducer is edge-terminated, with both diaphragms at ground voltage. Specifically, this ensures considerably reduced sensitivity to dust and humidity.

    No-Compromise Sound Design

    Transformerless circuitry permits a high degree of linearity and a large dynamic range. The self-noise of only 10 dB-A is practically inaudible, while at the same time, the TLM 107 features high level handling. The maximum sound pressure level of 141 dB SPL can be increased to 153 dB SPL via pre-attenuation (Pad). This enables the TLM 107 to transmit the sound of even the loudest instruments without distortion. The Low Cut settings of Linear, 40 Hz, and 100 Hz are precisely adapted to practical recording situations. Without side effects, the 40 Hz setting cuts interference noise below the range of fundamental tones (where 41 Hz is the frequency of the double bass open E string), while the 100 Hz setting is optimized for speech and vocals (where 100 Hz corresponds to the lowest notes of a baritone).

    Innovative Operating Concept

    For the first time, all of the microphone switch functions are controlled intuitively via a navigation switch. A visual highlight is the illuminated pattern display in the chrome ring, while the Pad and Low Cut status is displayed by LEDs to the left and right of the switch. In order not to distract singers, the switch and display are located on the back of the microphone. After 15 seconds, the displays are turned off automatically.

    Specifications
    Acoustical operating Pressure gradient transducer
    Directional patternOmnidirectional, wide angle cardioid, cardioid, hypercardioid, gure-8
    Frequency range20 Hz...20 kHz
    Sensitivity at 1 kHz into 1 kohm11 mV/Pa
    Rated impedance50 ohms
    Rated load impedance1 kohms
    Equivalent noise level, CCIR1)22 dB
    Equivalent noise level, A-weighted1)10 dB-A
    Signal-to-noise ratio, CCIR1) (rel. 94 dB SPL) 72 dB
    Signal-to-noise ratio, A-weighted1) (rel. 94 dB SPL)84 dB
    Maximum SPL for THD 0.5%2)141 dB
    with preattenuation -6 dB 147 dB
    with preattenuation-12 dB 153 dB
    Max. output voltage for THD>0.5%10 dBu
    Supply voltage (P48, IEC 61938)48 V ± 4 V
    Current consumption (P48, IEC 61938)3,2 mA
    Matching connectorXLR3F
    Weight approx.445 g
    Diameter 64 mm
    Length 145 mm