Description
Each of the ST-ACR products is an Audio Controlled Relay in the STICK-ON series. These products are designed for quick, convenient installation, and reliable operation in a variety of control applications. The ST-ACR-1M is designed to switch on low-level sources, such as microphones or mic-level sources.
Two multiturn trimmers are provided. The SENS potentiometer adjusts the audio input sensitivity. A threshold LED facilitates accurate adjustment. The module can be set to trigger on signals between -65 dBu and -20 dBu. The DELAY control sets the time required for the relay to release when the audio drops below the threshold. The adjustment range is from 0.5 seconds to 5 seconds.-
Features:
- Switching Controlled by Audio Signal
- Sensing of Microphone-Level Signal
- Silence Sensing
- DPDT Switching Contacts
- Open-Collector SLAVE Output
| Audio Input: | 10 k balanced bridging |
| Input Connections: | May be connected balanced or unbalanced |
| Control Output: | Open-collector @ 25 mA suitable to drive indicators or slave LCR relay |
| Indicators: | Audio threshold LED (for setting sensitivity) |
| Retrigger delay: | 250 ms |
| Contacts: | Double-pole-double-throw |
| Max. Switching Power: | 60 W, (220 Vdc, 125 Vac, 2A0 |
| Activation response time: | 25 ms |
| Input Sensitivity: | -65 dBu to -20 dBu (adjustable) |
| Relay Release Delay: | 0.5 sec. to 5.0 sec. nominal (adjustable) |
| Power Requirement: | GROUND-REFERENCED, 24 to 33 Vdc @ 50 mA* * Assumes 20 mA max load at SLAVE output |
| Ambient Operating Environment: | 0 degrees C to 55 degrees C |
Each of the ST-ACR products is an Audio Controlled Relay in the STICK-ON series. These products are designed for quick, convenient installation, and reliable operation in a variety of control applications. The ST-ACR-1M is designed to switch on low-level sources, such as microphones or mic-level sources.
Two multiturn trimmers are provided. The SENS potentiometer adjusts the audio input sensitivity. A threshold LED facilitates accurate adjustment. The module can be set to trigger on signals between -65 dBu and -20 dBu. The DELAY control sets the time required for the relay to release when the audio drops below the threshold. The adjustment range is from 0.5 seconds to 5 seconds.-
Features:
- Switching Controlled by Audio Signal
- Sensing of Microphone-Level Signal
- Silence Sensing
- DPDT Switching Contacts
- Open-Collector SLAVE Output
| Audio Input: | 10 k balanced bridging |
| Input Connections: | May be connected balanced or unbalanced |
| Control Output: | Open-collector @ 25 mA suitable to drive indicators or slave LCR relay |
| Indicators: | Audio threshold LED (for setting sensitivity) |
| Retrigger delay: | 250 ms |
| Contacts: | Double-pole-double-throw |
| Max. Switching Power: | 60 W, (220 Vdc, 125 Vac, 2A0 |
| Activation response time: | 25 ms |
| Input Sensitivity: | -65 dBu to -20 dBu (adjustable) |
| Relay Release Delay: | 0.5 sec. to 5.0 sec. nominal (adjustable) |
| Power Requirement: | GROUND-REFERENCED, 24 to 33 Vdc @ 50 mA* * Assumes 20 mA max load at SLAVE output |
| Ambient Operating Environment: | 0 degrees C to 55 degrees C |